spiegel_podman/test/system/050-stop.bats
Valentin Rothberg d54478d8ea container stop: release lock before calling the runtime
Podman defers stopping the container to the runtime, which can take some
time.  Keeping the lock while waiting for the runtime to complete the
stop procedure, prevents other commands from acquiring the lock as shown
in #8501.

To improve the user experience, release the lock before invoking the
runtime, and re-acquire the lock when the runtime is finished.  Also
introduce an intermediate "stopping" to properly distinguish from
"stopped" containers etc.

Fixes: #8501
Signed-off-by: Valentin Rothberg <rothberg@redhat.com>
2021-01-14 17:45:30 +01:00

98 lines
3.3 KiB
Bash

#!/usr/bin/env bats
load helpers
# Very simple test
@test "podman stop - basic test" {
run_podman run -d $IMAGE sleep 60
cid="$output"
# Run 'stop'. Time how long it takes.
t0=$SECONDS
run_podman stop $cid
t1=$SECONDS
# Confirm that container is stopped. Podman-remote unfortunately
# cannot tell the difference between "stopped" and "exited", and
# spits them out interchangeably, so we need to recognize either.
run_podman inspect --format '{{.State.Status}} {{.State.ExitCode}}' $cid
is "$output" "\\(stopped\|exited\\) \+137" \
"Status and exit code of stopped container"
# The initial SIGTERM is ignored, so this operation should take
# exactly 10 seconds. Give it some leeway.
delta_t=$(( $t1 - $t0 ))
[ $delta_t -gt 8 ] ||\
die "podman stop: ran too quickly! ($delta_t seconds; expected >= 10)"
[ $delta_t -le 14 ] ||\
die "podman stop: took too long ($delta_t seconds; expected ~10)"
run_podman rm $cid
}
# Test fallback
# Regression test for #2472
@test "podman stop - can trap signal" {
# Because the --time and --timeout options can be wonky, try three
# different variations of this test.
for t_opt in '' '--time=5' '--timeout=5'; do
# Run a simple container that logs output on SIGTERM
run_podman run -d $IMAGE sh -c \
"trap 'echo Received SIGTERM, finishing; exit' SIGTERM; echo READY; while :; do sleep 1; done"
cid="$output"
wait_for_ready $cid
# Run 'stop' against it...
t0=$SECONDS
run_podman stop $t_opt $cid
t1=$SECONDS
# ...the container should trap the signal, log it, and exit.
run_podman logs $cid
is "$output" ".*READY.*Received SIGTERM, finishing" "podman stop $t_opt"
# Exit code should be 0, because container did its own exit
run_podman inspect --format '{{.State.ExitCode}}' $cid
is "$output" "0" "Exit code of stopped container"
# The 'stop' command should return almost instantaneously
delta_t=$(( $t1 - $t0 ))
[ $delta_t -le 2 ] ||\
die "podman stop: took too long ($delta_t seconds; expected <= 2)"
run_podman rm $cid
done
}
# Regression test for #8501
@test "podman stop - unlock while waiting for timeout" {
# Test that the container state transitions to "stopping" and that other
# commands can get the container's lock. To do that, run a container that
# ingores SIGTERM such that the Podman would wait 20 seconds for the stop
# to finish. This gives us enough time to try some commands and inspect
# the container's status.
run_podman run --name stopme -d $IMAGE sh -c \
"trap 'echo Received SIGTERM, ignoring' SIGTERM; echo READY; while :; do sleep 1; done"
# Stop the container in the background
$PODMAN stop -t 20 stopme &
# Other commands can acquire the lock
run_podman ps -a
# The container state transitioned to "stopping"
run_podman inspect --format '{{.State.Status}}' stopme
is "$output" "stopping" "Status of container should be 'stopping'"
run_podman kill stopme
# Exit code should be 137 as it was killed
run_podman inspect --format '{{.State.ExitCode}}' stopme
is "$output" "137" "Exit code of killed container"
}
# vim: filetype=sh